top of page

Case Study Library

Coastal concrete column reinforcement case study thumbnail showing a beachfront home with damaged concrete support columns before carbon fiber strengthening.

Coastal Concrete Column Reinforcement with Carbon Fiber – Oceanside Drive, Scituate, MA

Carbon fiber and corrosion-protection system used to repair and strengthen coastal concrete columns exposed to saltwater and harsh marine conditions along Oceanside Drive in Scituate, MA.

Deteriorated concrete column restored using carbon fiber reinforcement and corrosion protection at industrial plant.

CFRP Column Repair with Integrated Corrosion Protection – Smithfield Plant, Crete, NE

Structural repair of deteriorated concrete support columns using carbon fiber reinforcement and corrosion protection at the Smithfield Plant in Crete, Nebraska.

Cracked CMU retaining wall before repair alongside completed carbon fiber reinforcement system.

CFRP Reinforcement of Residential Retaining Wall – Woodland Hills, CA

Carbon fiber reinforcement installed on a deteriorated residential retaining wall in Woodland Hills, CA to restore structural integrity and prevent further displacement.

Construction site slab with identified missing post-tension tendons before carbon fiber strengthening installation.

CFRP Strengthening for Post-Tensioned Slab – Milwaukee, Wisconsin

CFRP strengthening solution used to reinforce a post-tensioned slab after missing tendons were discovered during a high-rise construction project.

Carbon fiber reinforcement applied to cracked industrial holding tanks at a Southern California chemical processing facility.

CFRP Reinforcement of Industrial Holding Tanks – Southern California

CFRP confinement and crack repair applied to deteriorated concrete holding tank lids and perimeter walls at an industrial processing facility.

Industrial CMU block wall reinforced with carbon fiber U-wrap and flexural strengthening at a Southern California facility.

CFRP Reinforcement of Industrial CMU Block Wall – Southern California

CFRP U-wrap and flexural reinforcement applied to a cracked CMU block wall and deteriorated door opening at an industrial facility.

CFRP strengthening of a high-rise roof slab for cell tower installation using SRS-600UNI carbon fiber and structural epoxy.

CFRP Roof Slab Strengthening for Cell Tower Installation

CFRP strengthening of an existing high-rise roof slab to support new cell tower loads without demolition or disruption.

CFRP strengthening of a CMU train tunnel wall for Canada Line SkyTrain, improving structural integrity and passenger safety.

CFRP Strengthening of CMU Train Tunnel Wall – Vancouver, BC

CFRP reinforcement applied to a cracked CMU train tunnel wall to restore structural integrity and enhance passenger safety for Canada Line SkyTrain.

Carbon fiber straps installed on a bowed CMU basement wall for structural stabilization during a residential foundation repair in Toms River, NJ.

Carbon Fiber Bowed Basement Wall Stabilization – Toms River, NJ

Carbon fiber reinforced polymer straps installed to stabilize a bowed CMU basement wall and prevent further inward movement.

District of Columbia National Guard Joint Force Headquarters building featured in the SRS case study on CFRP strengthening of double T parking garage beams.

CFRP Strengthening for National Guard Parking Garage – Arlington, VA

Structural strengthening of deteriorated inverted T-beams at the National Guard Joint Force Headquarters parking garage using CFRP U-wrap reinforcement.

Coastal condominium in the Outer Banks showing hurricane-related structural damage prior to carbon fiber strengthening by Structural Reinforcement Solutions.

Carbon Fiber Hurricane Damage Strengthening – Outer Banks, NC

A multi-story coastal condominium severely damaged by Category 4 hurricane forces is structurally reinforced and restored using carbon fiber strengthening systems.

Retaining wall repair and carbon fiber strengthening installed on a residential property to stabilize cracking and structural deterioration.

Carbon Fiber Retaining Wall Repair & Structural Strengthening – California Case Study

A failing California retaining wall with severe cracking and corner separation was permanently repaired and strengthened using SRS carbon fiber systems for long-term structural stability.

Tilt-up precast concrete panel undergoing structural strengthening with temporary bracing during a commercial construction project.

Tilt-Up Precast Concrete Panel Strengthening

A tilt-up concrete panel required carbon fiber reinforcement after an elevator shaft conflict forced removal of embedded reinforcement during construction.

Brick column inside the Owens-Illinois glass factory and exterior plant view, representing carbon fiber reinforcement applied to strengthen aging industrial support structures.

Carbon Fiber Brick Column Strengthening

A historic Owens-Illinois glass plant in Zanesville, Ohio required reinforcement of a critical brick support column carrying more than 300 tons of molten glass. SRS provided a rapid, engineered carbon fiber strengthening solution that fully encapsulated the column, restored load-carrying capacity, and allowed the plant to maintain production schedules with minimal downtime.

Crew preparing a damaged commercial retaining wall for carbon fiber repair and strengthening along a roadside slope.

Carbon Fiber Reinforcement for Retaining Wall Restoration at Occidental College

A deteriorating 60-foot retaining wall at Occidental College in Los Angeles required a long-term structural repair solution after decades of cracking, section loss, and outdated reinforcement from its WWII-era construction. SRS provided a modern CFRP strengthening design using SRS-600UNI and SRS-660BI to stabilize the wall, restore flexural and shear capacity, and prepare it for future tieback loads where needed.

Construction crew applying carbon fiber reinforcement to a concrete bridge pier cap beneath a roadway as part of a structural strengthening project.

Carbon Fiber Bridge Strengthening

A rural Indiana bridge spanning the Patoka River showed significant deterioration at its pier caps, where aging horizontal reinforcement was no longer capable of supporting cantilevered loads. Structural Reinforcement Solutions partnered with LAN Construction and county engineers to develop a long-term carbon fiber strengthening system that restored structural integrity without major demolition.

Camano Island sea wall showing storm damage compared to restored wall after carbon fiber reinforcement installation.

Carbon Fiber Sea Wall Strengthening

A deteriorated coastal sea wall on Camano Island was restored and structurally reinforced using carbon fiber systems designed to withstand tides, storms, and marine exposure.

Carbon fiber reinforcement strips installed on a bowing retaining wall at an Oregon elementary school prior to structural tieback installation.

Carbon Fiber & Tieback Reinforcement for School Retaining Wall Stabilization

A retaining wall at an elementary school in Happy Valley, OR was exhibiting horizontal bowing and extensive cracking due to inadequate restraint and unexpected earth pressures. Structural Reinforcement Solutions (SRS) provided a carbon fiber strengthening system combined with tiebacks to permanently stabilize the wall and restore long-term safety.

Lift equipment and crew applying vertical carbon fiber reinforcement strips to a tall CMU warehouse wall during a commercial wall strengthening project.

Carbon Fiber Reinforcement for CMU Wall Strengthening

When foundation lifting raised concerns about the flexural capacity of 22-foot-tall CMU block walls, Structural Reinforcement Solutions provided a carbon fiber strengthening plan to reinforce each pier location using high-strength unidirectional CFRP. The reinforcement ensured safe foundation adjustments without damaging the existing wall structure.

Carbon fiber reinforcement installed on a post-tensioned concrete slab during structural strengthening work at a multi-story residential building construction site.

Carbon Fiber Reinforcement for Post-Tensioned Slab Repair

A post-tensioned concrete slab in Vero Beach required reinforcement after misaligned tendons caused flexural stress and shear concerns. SRS designed a carbon fiber strengthening solution that restored structural capacity while minimizing downtime.

Carbon fiber reinforcement applied to cracked structural slab edge during embed strengthening project in Denver.

Concrete Slab Embed Reinforcement Using Carbon Fiber

A high-rise condo project in Denver, Colorado discovered cracking around embedded plates on a 27" post-tensioned slab. Engineers determined that inadequate confinement threatened pullout failure of the embedded anchors. SRS provided a rapid carbon fiber strengthening solution to restore structural integrity and allow drilling of new threaded rods without further cracking.

Crew installing carbon fiber reinforcement on a cracked concrete dock surface at a marina to restore structural integrity.

Carbon Fiber Concrete Dock Crack Reinforcement | Waterfront Structural Repair

Storm surges and winter king tides caused severe cracking and structural distress to a concrete dock at the Royal Vancouver Yacht Club in Coal Harbour, BC. SRS provided a non-corrosive carbon fiber strengthening system to stabilize the dock, confine cracking, and protect it from future storm damage in a minimally disruptive, marine-grade application.

Carbon fiber reinforcement installed on precast concrete beams during a commercial building strengthening project, showing CFRP strips applied to increase flexural capacity.

Carbon Fiber Beam Strengthening

A two-story commercial building in Pueblo, CO required structural reinforcement after added HVAC loading exceeded the capacity of the existing precast double-tee beams. SRS provided an engineered CFRP strengthening solution using SRS-600UNI, reducing material requirements while delivering rapid, cost-effective beam rehabilitation.

Carbon fiber reinforced retaining wall repair in Palm Springs, CA, showing CFRP vertical and horizontal strengthening on a failing concrete wall.

California’s Largest Carbon Fiber Retaining Wall Repair Project | Palm Springs CFRP Strengthening

A 650-foot retaining wall supporting six luxury homes in Palm Springs was exhibiting severe cracking, tilting, and soil-pressure instability. SRS engineered a hybrid reinforcement system using CFRP and steel tiebacks to restore structural integrity, increase load distribution, and prevent further wall movement in this high-risk seismic region.

Carbon fiber reinforcement being applied to concrete bike path columns to address spalling and confinement deficiencies.

Elevated Bike Path Column Reinforcement Using CFRP

A newly constructed elevated bike path in St. Louis experienced spalling and insufficient confinement at the tops of its 30" concrete columns. SRS provided a CFRP-based solution that restored structural performance while minimizing disruption to the project.

Crew applying carbon fiber reinforcement and epoxy materials to deteriorated timber piles during structural rehabilitation at a hillside residential complex.

Timber Pile Rehabilitation with Carbon Fiber Reinforcement

Severe deterioration of hillside timber piles threatened a multi-building residential complex in Portland, OR. SRS engineered a carbon fiber rehabilitation plan to restore structural capacity while overcoming tight access and environmental challenges.

Parking garage structural repair using FRP reinforcement, showing deteriorated concrete columns, carbon fiber wrap installation, and completed CFRP strengthening performed by SRS.

Parking Garage Structural Repair Using FRP Reinforcement

A deteriorating parking structure with cracked concrete and exposed rebar required a cost-effective reinforcement strategy. SRS provided a carbon fiber strengthening solution that restored load capacity, halted corrosion, and extended the service life of the garage.

Carbon fiber reinforcement installed to strengthen structural slabs during renovation at the historic Aladdin Hotel in Kansas City, showing interior CFRP application and exterior façade of the building.

Carbon Fiber Reinforcement at the Historic Aladdin Hotel – Structural Strengthening Project

A historic downtown hotel needed a structural upgrade to accommodate new mechanical systems without compromising slab performance. SRS designed a carbon fiber reinforcement system that strengthened the slabs while maintaining the building’s historic integrity.

CFRP wraps installed on concrete bridge pier columns for structural strengthening and corrosion protection as part of a DOT-directed rehabilitation project.

CFRP-Wrapped Bridge Pier Columns Undergoing Structural Strengthening

Bridge columns exposed to water and environmental wear required protective strengthening. SRS installed CFRP wraps to increase durability, extend service life, and meet DOT performance requirements with minimal disruption to traffic.

Telecom tower support columns showing concrete deterioration prior to carbon fiber repair, with inset map of project location in the Florida Keys.

Telecom Tower Column Condition Before Carbon Fiber Strengthening

Deteriorated concrete columns supporting critical telecom infrastructure required immediate reinforcement. SRS restored structural capacity using CFRP systems, improving performance while minimizing downtime for essential communication services.

bottom of page